Single harmonic control efficiency ≥95%.
1.Product Features
1. Real-time display of power factor φ, voltage, current, active power, reactive power, voltage total harmonic distortion rate, current total harmonic distortion rate, frequency, capacitance output display and switching status and various protection overrun alarms and other information.
2. Capacitor input delay and removal delay can be set separately, with high compensation efficiency, input and removal thresholds can be preset and high compensation accuracy.
3. It has the functions of harmonic voltage and current measurement and protection, and power failure protection; it has two working modes of manual compensation and automatic compensation; it has standard field bus communication interface which is convenient for connecting to the intelligent switch cabinet system.
4. Adhering to the people-oriented design concept, modular assembly, full digital design, the human-machine interface adopts a large-screen English LCD display.
5. Signal AC sampling, strong anti-interference ability, avoid misoperation, high work reliability; can accurately judge reactive power and power factor, and avoid oscillation switching phenomenon.
2.Technical Parameter
Environmental condition |
Height above sea level |
≤2500m |
Temperature |
-20°C~60°C |
|
|
No conductive dust, no corrosive gas,no explosive and flammable medium around the controller. The installation site should be no violent vibration and erosion of snow and rain. |
|
Input/output signal |
Sampling voltage |
Phase splitting compensation:L1/L2/L3 phase voltage |
Total Compensation:L1/L3 Phase |
||
Sample current |
Phase splitting compensation:the each phase current of L1/L2/L3 is 0~5A |
|
Total compensation:L2 is 0~5A |
||
Control output |
Relay:5A/250V |
|
Thyristor switch:12V/30mA |
||
Display Function |
|
LCD monitor data refresh cycle≤1S |
Measurement accuracy |
Voltage |
±0.5% |
Current |
±0.5% |
|
Power factor |
±1.0% |
|
Active factor |
±1.0% |
|
Reactive factor |
±1.0% |
|
Frequency |
±0.1Hz |
|
ID setting |
ID number |
001~255 |
Communication rate |
4800~38400bps |
|
Measurement data |
Voltage |
100V~290V |
Current |
0~6000A |
|
Sensitivity |
50mA(Secondary) |
|
Power factor |
Lag 0.200~ahead 0.200 |
|
Power supply |
220V±20% |
|
Testing Frequency |
47~53Hz |
|
Active power |
0~6553KW |
|
Reactive power |
0~6553Kvar |
|
THD-V |
0~100% |
|
THD-I |
0~100% |
|
Communication interface data |
Interface |
RS-485 |
Protocol |
MODBUS communication protocol |
|
Setting data |
Current transformer ratio |
Rate value:1~1200 |
Delay time |
Contactor:5 S~100 S Thyristor switch 0.1S~30S |
|
Target power factor |
Lag 0.9~ Ahead 1.0 |
|
Over voltage |
230V~290V or close |
|
Under voltage |
180V~200V or close |
|
Off limit |
0.5-1.2 |
|
Harmonic voltage protection |
1.0%~50% or close |
|
Harmonic current protection |
180V~200V or close |
|
Phase splitting compensation capacitor branches |
0~7 |
|
Three-splitting compensation capacitor branches |
0~21 |
|
Capacitor branches |
Three times phase splitting branches + three branches≤21 |
|
Capacitor preset |
0~999Kvar/Branch |